NFPA70 / NEC500
Class I Division 1
Is a hazardous location in which flammable gases or vapors such as natural gas or gasoline vapor may be present in the air in sufficient quantities to be explosive or ignitable in normal operation conditions.
Class I Division 2
Is a hazardous location in which flammable gases or vapors such as natural gas or gasoline vapor may be present in the air in sufficient quantities to be explosive or ignitable in abnormal conditions.
Class II Division 1
Is a location made hazardous by the presence of combustible dust. Finely pulverized material, suspended in the atmosphere, can cause as powerful an explosion as one occurring at a petroleum refinery in normal operation conditions.
Class II Division 2
Is a location made hazardous by the presence of combustible dust. Finely pulverized material, suspended in the atmosphere, can cause as powerful an explosion as one occurring at a petroleum refinery in abnormal conditions.
Class III Division 1
Are areas where there are easily-ignitable fibers or flyings present, due to the types of materials being handled, stored, or processed. The fibers and flyings are not likely to be suspended in the air, but can collect around machinery or on lighting fixtures and where heat, a spark or hot metal can ignite them in normal operation conditions.
Class III Division 2
Are areas where there are easily-ignitable fibers or flyings present, due to the types of materials being handled, stored, or processed. The fibers and flyings are not likely to be suspended in the air, but can collect around machinery or on lighting fixtures and where heat, a spark or hot metal can ignite them in abnormal conditions.
Trasformation Ex
The EX type electric forklift truck is suitable for use in:
Class I Division 1 Group D
Class I Division 2 Group D
Class II Division 1 Group F and G
Class II Division 2 Group F and G
Class III Division 1
Class III Division 2
In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500.
Features:
Temperature Class T3C
Explosion proof electric motors
Monitoring of surface temperatures
Monitoring of earth leakage
Visual alarm signals
Installation and conversion of components suitable for use in the operation zone
Load handling device covered with spark-proof material
Trasformation EE
The EE type electric forklift truck is suitable for use in:
Class I Division 2 Group D
Class II Division 2 Group F and G
Class III Division 1
Class III Division 2
In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500
Features:
Temperature Class T3C
Electric-powered motors mechanically protected by enclosures
Monitoring of surface temperatures
Monitoring of earth leakage
All components are protected and certified for the operation zone
Load handling device covered with spark-proof material
Trasformation DX
The DX type electric forklift truck is suitable for use in:
Class I Division 1 Group D
Class I Division 2 Group D
Class II Division 1 Groups F and G
Class II Division 2 Groups F and G
Class III Division 1
Class III Division 2
Trasformation DV
The DY type electric forklift truck is suitable for use in
Class I Division 2 Group D
Class II Division 2 Group F and G
Class III Division 1
Class III Division 2
In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500
Links
PRIVACY POLICY
COOKIE POLICY
FAQ
SUPPORT
Contacts
Headquarter
Via Marconi 29/31, 20812 Limbiate (MB) - Italia
Phone (+39) 02 99 08 11 | Fax (+39) 02 99 05 24 88
Sales Department
Emission Control Systems Catalytic Department
After Sales
Need more Information?
GET A QUOTE
CONTACT OUR TEAM