NFPA70 / NEC500

Class I Division 1

 

Is a hazardous location in which flammable gases or vapors such as natural gas or gasoline vapor may be present in the air in sufficient quantities to be explosive or ignitable in normal operation conditions.

Class I Division 2

 

Is a hazardous location in which flammable gases or vapors such as natural gas or gasoline vapor may be present in the air in sufficient quantities to be explosive or ignitable in abnormal conditions.

Class II Division 1 

Is a location made hazardous by the presence of combustible dust. Finely pulverized material, suspended in the atmosphere, can cause as powerful an explosion as one occurring at a petroleum refinery in normal operation conditions.

Class II Division 2

Is a location made hazardous by the presence of combustible dust. Finely pulverized material, suspended in the atmosphere, can cause as powerful an explosion as one occurring at a petroleum refinery in abnormal conditions.

Class III Division 1

Are areas where there are easily-ignitable fibers or flyings present, due to the types of materials being handled, stored, or processed. The fibers and flyings are not likely to be suspended in the air, but can collect around machinery or on lighting fixtures and where heat, a spark or hot metal can ignite them in normal operation conditions.

Class III Division 2

Are areas where there are easily-ignitable fibers or flyings present, due to the types of materials being handled, stored, or processed. The fibers and flyings are not likely to be suspended in the air, but can collect around machinery or on lighting fixtures and where heat, a spark or hot metal can ignite them in abnormal conditions.

Trasformation Ex

The EX type electric forklift truck is suitable for use in:

Class I Division 1 Group D
Class I Division 2 Group D
Class II Division 1 Group F and G
Class II Division 2 Group F and G
Class III Division 1
Class III Division 2

In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500.

Features:

^

Temperature Class T3C

^

Explosion proof electric motors

^

Monitoring of surface temperatures

^

Monitoring of earth leakage

^

Visual alarm signals

^

Installation and conversion of components suitable for use in the operation zone

^

Load handling device covered with spark-proof material

Trasformation EE

The EE type electric forklift truck is suitable for use in:

^

Class I Division 2 Group D

^

Class II Division 2 Group F and G

^

Class III Division 1

^

Class III Division 2

In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500
Features:

^

Temperature Class T3C

^

Electric-powered motors mechanically protected by enclosures

^

Monitoring of surface temperatures

^

Monitoring of earth leakage

^

All components are protected and certified for the operation zone

^

Load handling device covered with spark-proof material

Trasformation DX

The DX type electric forklift truck is suitable for use in:
Class I Division 1 Group D
Class I Division 2 Group D
Class II Division 1 Groups F and G
Class II Division 2 Groups F and G
Class III Division 1
Class III Division 2

Trasformation DV

The DY type electric forklift truck is suitable for use in

^

Class I Division 2 Group D

^

Class II Division 2 Group F and G

^

Class III Division 1

^

Class III Division 2

^

In accordance with table 4.2(a) of regulatory norm NFPA70/NEC500